2014new Stego Airflow Monitor

FOB Reference Price:Get Latest Price
US $13-20 / Pieces | 100 Piece/Pieces (Min. Order)
Report Suspicious Activity
Overview
Quick Details
Place of Origin:
Zhejiang, China (Mainland)
Brand Name:
Saip
Model Number:
LC 013 / LCF 013
Usage:
Temperature Sensor
Theory:
Ultrasonic Sensor
Contact type:
reed / magnet contact
Normally closed (NC):
switch contact open when air is flowing
Normally open (NO):
switch contact closed when air is flowing
Max. switching voltage:
NC: 240VDC (UL), 240V AC/DC (VDE) / NO: 60VDC
Max. switching current:
NC: DC 500mA / NO: DC 170mA
Max. switching capacity:
10W (resistive load)
Switching threshold of airflow velocity:
> 2.5m/s (hysteresis: > 1m/s)
Max. airflow velocity:
50m/s
Contact resistance:
< 370mOhm (with wire)
Max. air humidity:
70% RH (not precipitating)
SupplyAbility
SupplyAbility:
50000 Piece/Pieces per Quarter
Packaging & Delivery
Packaging Details
nuetral,also can do as customers'order
Port
Ningbo/Shanghai
Lead Time :
3-5days after getting the payment

2014New Stego Airflow Monitor ,

Airflow Monitor Stego airflow monitor LC013/LCF013 LC013/LCF013

 

Product Description

 low Monitor/airflow sensor/ airflow meter

1. Mechanical switch contact   Stego airflow monitor LC013/LCF013
2. Versatile fields of application     Stego airflow monitor LC013/LCF013
3. Small size     Stego airflow monitor LC013/LCF013
4. Easy to connect    Stego airflow monitor LC013/LCF013

The airflow monitor (NC/NO) is designed to indicate the loss of air movement of a fan or filter fan. The contact detects the loss of air movement caused by fan failure or blocked filter media regardless of direction of air. Its simple mechanical operation makes is a viable alternative to electronic monitoring systems.    Stego airflow monitor LC013/LCF013

Application:

  The LC 013 is used as a signal contact to monitor fans or filter fans in stationary, self-contained Protection Class I enclosures. It can be connected to monitoring systems with remote control or can directly switch alarm devices, such as LED's or signal lamps. Loads with capacities exceeding the indicated switching capacity must be switched via a relay, e.g. our electronic relay SM 010. The airflow monitor with NC contact closes upon loss of air movement, i.e. it indicates fan failure (e.g. red signal lamp). The NO contact closes when fan is in operation and serves as optical function display (e.g. green signal lamp).     Stego airflow monitor LC013/LCF013
Technical Data:

Contact type 

reed / magnet contact

Normally Closed (NC) 

switch contact open when air is flowing

Normally Open (NO) 

switch contact closed when air is flowing

Max. switching voltage 

NC: 240VDC (UL), 240V AC/DC (VDE) / NO: 60VDC

Max.switching current 

NC: DC 500mA / NO: DC 170mA

Max. switching capacity 

10W (resistive load)

Switching threshold of airflow velocity 

>2.5m/s (hysteresis:>1m/s)

Max.airflow velocity 

50m/s

Contact resistance 

<370m (with wire)

Max. air humidity 

70% RH (not precipitating)

Service life 

>100,000 cycles

Connection

2×single strand AWG26, length 500mm, tip of stranded

wire 5mm stripped and tinned (NC:black, NO:blue)

Mounting 

alternatively integrated integrated in protective grille (see table).

mounting clamp or mounting clip

Casing 

plastic according to UL94-HB, black

Fitting position 

bidirectional tab perpendicular to airflow

Operating / Storage temperature 

-20 to +50°C (-4 to +122°F) / -20 to +80°C (-4 to +176°F)

Protection type 

IP20

 Note: The product of switching voltage and switching current must not exceed 10W. The max. voltage and max. current must not be exceeded, not even short-term (voltage/current peaks). The resulting voltage and current peaks of inductive or capacitive loads must be restricted by a contact protection circuit.

Airflow monitor integrated in protective grille:

Stego airflow monitor LC013/LCF013

Stego airflow monitor LC013/LCF013

Example of connection:

 

Installation notes:

1. The airflow monitor must not be installed in the impact range of permanent magnets or ferrous metals as the built-in permanent magnet will move unintentionally and consequently can not move in dependence with the air flow.
2. A suitable distance from electromagnetic fields, e.g. generated by transformers, motors, etc., must be maintained as otherwise the contact may switch incorrectly with the frequency of the power supply. Interferences must be checked with an oscillograph and the mounting position of the airflow monitor should be adjusted if necessary.
3. Avoid installing the airflow monitors in areas where air pockets or turbulence can be expected.
4. Ambient air with a high dust contect should be avoide.
As there are many different conditions of use, suitability of this product must be assessed by the end user in its final application.

The photos for different parts:

Stego airflow monitor LC013/LCF013

 

 

 

More products

 More similiar products:

Stego airflow monitor LC013/LCF013

 

 

 

Company Information

 For our Company:

Stego airflow monitor LC013/LCF013

On Exhibition:

 

 

 

Certifications

 Certificate:

Stego airflow monitor LC013/LCF013

 

 

 

contact way

  

More products,you can visit our web : www.saipgroup.com   to check.

Contact Person:Maryzhang

Skype:saip308

Mob:0086-13695878629

Tel:0086-0577-61770731

Fax:0086-0577-62760731-8008